Hip2P Camera Software4/8/2021
After device connected, it will show a blue triangle on UID or name; if shows, means device do not connnect.
Hip2P Camera Software Software Can ManageThe management software can manage Max 96 front-end network monitoring devices; can set and control any device, and other functions; can support 14689162536 pictures display on one screen, and two-way voice talk back, logs retrieval, and other functions.With powerful function, friendly interface, and simple operation, it is convenient for users to realize networking applications for large-scale remote network monitoring system.Statement: 1. The contents described in this manual may exsit some difference with the vesion you are using.
If you have some questions can not be solved, please contact our technical support department or products supplier. The contents in this manual will update irregularly, our company reserves the rights without prior notice. Installtions 1.1. Installation requirements Hardware enviroment: 1. Pentium IV series, CPU basic frenquency more than 2.0G 2. G memory 3. After installation, it will show below icon on desktop: In the program bar will show following interface: 2. CMS detailed instruction 2.1. Hip2P Camera Software Password Is EmptyLogin and instruction Log in When log in, the default user name is admin and password is empty, click OK to enter into CMS Main interface. Exit Only the users with admin permissions can exit from CMS, user and guest can not exit from CMS. When exit from CMS, you need to input the admin permissionss user name and password. Software interface instruction The software interface as shown in above, mainly divided to 6 sections: 1 System button bar 2 tab bar 3 device list 4 real-time preview 5 PTZ control 6 Alarm info list System button list: Help button, click it to open CMS instruction Hidden button, click it then software hide into system tray Maximize button, click it then software cover entire screen Exit button, click it then software pop up Exit reminder Tab bar: Logo information click it then switch to image preview interface click it then switch to recording playback interface click it then switch to setting interface click it then switch to logo operation interface logout user and switch user click it then exit CMS Device List: List mode According to user configuration listing level to show area,setting,and channel Current screen show current connected device on screen, only shows in list mode Real-time preview electronic zoom button, click it and use mouse to draw a area on the screen, then area magnification can be realized Voice talk back button, choose the window need to open talk back, then click talk back button, window status bar will show, talk back can be realized, only can open talk back of one device at the same time. Multi-image choosing button, click it to choose multi-image display, 1,4,6,8,9,16 image options. Hip2P Camera Software Full Screen DisplayingFull screen display button, click it then real-time preview area will be full screen displaying. Alarm message list shrink or extend button, click it that alarm message list shrink, click again then alarm message list extend. Device management 2.3.1. Add device Before using the CMS, you need to add device and configuration. Click setting button in tab bar, enter into device management page. Add list list When run software initially, default list tree is empty. After filling in name in area name column, click ok to add a area in list tree. Because of the added area is the first area, so this area do not exist belongs area, the area is empty. Add area into device tree Modify the name of selected area Delete the selected area Add device manually, click it to pop up dialog box of add device click it, then pop-up dialog box of editing device Delete the selected device add the searched devices to selected area click it to search the devices in LAN choose all devices in searching list Add device Search to add device in LAN Clicking search button, the CMS will search out all devices in LAN, then select the device needed to add in search list, and select area, click button to add device, thus you can add selected device to this area. Add device manually Click button, it will pop-up below dialog box of add device, as shown in below: UID UID of the device, each device has different UID Name name of the device, it is user-defined. Max 15 Chinese characters. Note: After Enter name, the device tree in preview window only display device name, dont display device IP Address. Password login password of the device, default is admin Area displaying area of the device After filling in all required information, click OK to finish device adding. Image preview After configured device, clicking previewbutton in Tab bar,then back to main interface of monitoring, the default display way of device tree is list tree. You can switch displaying group and list information by clicking group and list in device tree. The default display images is 4 image segmentation, support Max 36 pictures. When maximum image segmentation, it has 162536 image mode optional. If 25 or 36 images displaying, we suggest use more than i3 CPU and independent video card. In list mode, please double click device UID or name, or drag UID to windows directly, then it can display image.
0 Comments
Leave a Reply.AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |